Services

Engineering services for existing & new structures.

A complete consultancy and testing capability — investigate, diagnose, design and supervise — backed by an ISO-certified laboratory.

01 · Consultancy

Existing Structures

Investigate, diagnose and rehabilitate ageing or distressed assets — from first condition survey to supervised repair.

  • Consulting for restoration & rehabilitation
  • Structural condition assessment
  • Structural assessment & strengthening design
  • Durability assessment (remaining service life)
  • Repair design & specifications
  • Repair supervision — QA & QC
02 · Consultancy

New Structures

Verify quality and design durability into new construction before defects become liabilities.

  • Concrete evaluation for construction defects
  • Durability planning
  • Thermal modeling
  • Cracking assessment
Diamond core drilling extracting a concrete sample from a structural wall
Ultrasonic pulse velocity testing with transducers on a concrete element
Macro view of a structural crack in concrete measured with a crack-width gauge
Structural load test with hydraulic jacks and dial gauges under a concrete slab
On-site & Laboratory Testing

Every test the diagnosis demands.

Non-destructive surveys, core sampling and load verification — performed to international standards on site and in the laboratory.

Core Testing

Core Testing

Concrete core samples are extracted and tested to determine actual in-situ strength and structural quality.

Sampling & Lab
Ultrasonic Pulse Velocity (UPV)
Non-destructive

Ultrasonic Pulse Velocity (UPV)

Non-destructive test to detect internal cracks, voids and material uniformity within concrete.

On-site (NDT)
Rebound Hammer Test
Non-destructive

Rebound Hammer Test

Rapid, non-destructive estimate of surface hardness and compressive strength — ideal for uniformity and comparative analysis across a site.

On-site (NDT)
Crack Analysis
Non-destructive

Crack Analysis

Assessment of cracks to identify type, cause and severity, informing the correct repair strategy.

On-site (NDT)
Window Opening Assessment
Non-destructive

Window Opening Assessment

Checks the stability and condition of structural openings for alignment and safety.

On-site (NDT)
Depth of Carbonation

Depth of Carbonation

Determines the extent of chemical change in concrete from environmental exposure — critical for predicting reinforcement corrosion and planning maintenance.

Sampling & Lab
Half-Cell Potential Test
Non-destructive

Half-Cell Potential Test

Measures the electrical potential of embedded steel to map corrosion risk and identify areas likely to corrode.

On-site (NDT)
Pull-Off Test

Pull-Off Test

Measures the adhesion strength of coatings, plasters, paints and cementitious layers.

Load & Capacity
Load Test

Load Test

Verifies the real performance of slabs, beams and structural elements under simulated or real loads — confirming design capacity and validating safety.

Load & Capacity
Pullout Test — Anchors, Rebars & Clamps

Pullout Test — Anchors, Rebars & Clamps

Determines the holding capacity of fasteners embedded in concrete or other substrates, ensuring the reliability of anchor bolts, rebar connections and façade fixings.

Load & Capacity
Start with an assessment

Tell us about your structure.